7-Port 10/100TX + 3-Port 10/100/1000T with 100/1000M
SFP Combo Industrial Managed Switch with DIDO

 
  • Supports DIDO (Digital input / output) function
  • X-Ring provides Ring recovery time of less than 10ms
  • Wide operating temperature range from -40°C to 75°C (-E model)
  • UL Class I Division II for Group A,B,C and D

  • Overview
  • Features
  • Specifications
  • Ordering Info
  • Applications
  • Downloads

OVERVIEW

The Lantech IES-2307C is a 7-Port 10/100Base-TX + 3 10/100/1000T with 100/1000 SFP Combo Industrial Switch with SNMP functionality. The SNMP features are including QoS for 4 queues, 801.q VLAN, IGMP snooping and query mode as well as SNTP and SMTP.

The IES-2307C supports Pro-Ring system, which covers X-Ring, Couple Ring, Dual Homing and Dual Ring. X-Ring provides a recovery time of less than 10ms for a ring of up to 250 switches. Couple Ring ensures network recovery protection between two X-Ring groups. Dual homing is to back up the X-Ring groups when connect to upper layer or core switch. It also supports Dual Ring, which can connect two rings without setting couple ports.

The IES-2307C DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IES-2307C will immediately send an email to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors into the auto alarm system and transfer the alarm information to IP network with email and SNMP.

Lantech-View is free bundle for 10 node version, in which it monitors and configures multiple Lantech industrial switches. Optional Lantech-View Pro can map up to unlimited user with auto-layout, configuration and discovery.

The IES-2307C is designed to meet with critical network environment with IP 30 enclosure and test under extensive Industrial EMI and Safety standards. With UL Class I Division II approval, the IES-2307C can be implemented in hazardous or explosive condition without accelerating the damage. It’s the best choice for inflammable environment where the liquid, gas and vapor etc might present the hazardous condition which generally to be find in mining, oil & gas, chemical, processing automation areas. It’s also suitable for surveillance, factory automation, transportation, telecom / ISP outside terminal, heavy industrial factory and other factory assembly lines.

FEATURES

2DI (Digital input) & 2DO (Digital output) function

Pro-Ring

  • X-Ring, Dual Homing, Couple Ring, and Dual Ring
  • Redundant backup feature and the recovery time less than 10ms for a ring of up to 250 switches*

Wide Operating Temperature (-40°C ~75°C) for -E model

Port Trunk with LACP

QoS, CoS supported

Security

  • Port Security: MAC address entries/filter
  • 10 IP address security management to prevent unauthorized intruder
  • Login Security: IEEE802.1X/RADIUS

IGMP Snooping & Query for Multi Media Applications

Supports Spanning Tree & RSTP

Support 802.1ab LLDP

UL Class I Division II Group A,B,C, D hazardous location

Bandwidth Control

  • Ingress Packet Filter and Egress Rate Limit
  • Broadcast/Multicast Packet Filter Control

System Event Log

  • System Log Server/Client
  • SMTP e-mail Alert
  • Relay Alarm Output System Events

SNMP Trap

  • Device cold start, Power status, Authentication failure, X-Ring topology changed, Port Link up/Link down, DIDO open/close

3000VDC EFT & 6000VDC ESD protection

Lantech-View, Windows-based Utility

  • Lantech-View 10 node version free bundle
  • LANTECH-View Pro up to unlimited user

Hardware Specification

Standard

IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3ab 1000Base-T
IEEE 802.3z Gigabit fiber
IEEE 802.3x Flow Control and Back-pressure
IEEE 802.3ad Port trunk with LACP
IEEE 802.1d Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN Tag
IEEE 802.1x User Authentication (RADIUS)
IEEE 802.1ab LLDP

Switch Architecture

Back-plane (Switching Fabric): 7.4Gbps

Transfer Rate

14,880 pps for 10Base-T Ethernet port
148,800 pps for 100Base-TX/FX Fast Ethernet port
1,488,000 pps for Gigabit Fiber Ethernet port

Packet Buffer

1Mbits

Mac Address

8K MAC address table

Flash ROM

4Mbytes

DRAM

32Mbytes

Connector

10/100TX: 7 x RJ-45
10/100/1000T/ Mini-GBIC Combo: 3 x RJ-45 + 3 x
100/1000 SFP sockets
RS-232 connector: RJ-45 type

Network Cable

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E cable
EIA/TIA-568 100-ohm (100m)
1000Base-T: 2-pair UTP/STP Cat. 5e or 6 cable
EIA/TIA-568 100-ohm (100m)

DI/DO

2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA

Optical Cable

Multi-mode: 50/125um~62.5/125um
Single mode: 9/125um
Available distance: 2km (Multi-mode)/30km (Single-mode)
Wavelength: 1310nm (Multi-mode/Single-mode)

LED

Power/ Power 1/ Power 2 (Green), Fault (Red), Ring Master Enable (Green), Ring Enable (Green)
Copper port : Link/Activity (Green), speed(Green/Orange) [Link/1000M]
SFP Fiber: Link/Activity (Green)

Protocol

CSMA/CD

Power Supply

24 VDC (9~56VDC), 12~36VAC (Optional), Redundant power with polarity reverse protects function and removable terminal block.

Reserve polarity protection

Present

Overload current protection

Present

Power Consumption

10.2 Watts

Operating Humidity

5% to 95% (Non-condensing)

Operating Temperature

-20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F (-E model)

Storage Temperature

-40°C~85°C / -40°F~185°F

MTBF

260818 hrs

Case Dimension

IP-30, 72mm (W) x 105mm (D) x 152mm (H)

Weight

1300 g

Installation

DIN rail and wall mount ear.

EMI & EMS

FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT), CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE EN61000-4-8, CE EN61000-4-11, CE EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4

Safety

UL, CUL, CE/EN60950-1
UL Class I Division II for Group A,B,C and D hazardous location

Stability Testing

IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration)

Warranty

5 years

Software Specification

Management

SNMP v1 v2c, v3/ Web/ Telnet/ CLI/ Lantech View Management

SNMP MIB

RFC 1215 Trap, RFC1213 MIBII, RFC 1157 SNMP MIB, RFC 1493 Bridge MIB, RFC 2674 VLAN MIB, RFC 1643 , RFC 1757, RSTP MIB, Private MIB

VLAN

Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries) / VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)
GVRP (256 Groups)

Port Trunk with LACP

LACP Port Trunk: 4 Trunk groups / Maximum 4 trunk members

LLDP

Supports LLDP to allow switch to advise its identification and capability on the LAN

Quality of Service

The quality of service determined by port, Tag and IPv4 Type of service, IPv4/IPv6 Different Service

Class of Service

Supports IEEE802.1p class of service, per port provides 4 priority queues

Spanning Tree

Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree

Pro-Ring

Supports X-Ring, Dual Homing, Couple Ring, and Dual Ring Topology. Provides redundant backup feature and the recovery time below 10ms*.

Port Security

Supports 100 entries of MAC address for static MAC and another 100 for MAC filter

Port Mirror

Supports 3 mirroring types: “RX, TX and Both packet”.

IGMP

Supports IGMP snooping v1,v2
256 multicast groups and IGMP query
Supports multicast filter

IP Security

Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.

Login Security

IEEE802.1X Authentication/RADIUS

System Log

System log record and remote system log server

SMTP

SMTP Server and 6 e-mail accounts for receiving event alert

SNTP

SNTP to synchronize system clock in Internet

DHCP

DHCP Client/ DHCP Server/ IP Relay functions

Flow Control

Supports Flow Control for Full-duplex and Back Pressure for Half-duplex

DNS

Provides DNS client feature and support Primary and Secondary DNS server.

Relay Alarm

Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V

SNMP Trap

Up to 3 Trap stations
Cold start, Port link up, Port link down, Authentication Failure, Private Trap for power status, Port Alarm configuration, Fault alarm, X-Ring topology change, DIDO open/close contact

Bandwidth Control

Supports ingress packet filter and egress packet limit
The egress rate control supports all of packet type and the limit rates are 100K~250Mbps.

Ingress filter packet type combination rules are Broadcast/Multicast/Unknown Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all of packet. The packet filter rate can be set from 100k to 250Mbps.

Firmware Update

TFTP firmware update, TFTP backup and restore.

Configuration
upload and download

Supports binary configuration file for system quick installation

ifAlias

Each port allows importing 128bit of alphabetic string of word on SNMP and CLI interface.

*The Recovery Time of X-Ring: G-SFP<10ms ; G-T<150ms


ORDERING INFOMATION

  • IES-2307C ……………….….......P/N: 8350-460
    7 10/100TX + 3 10/100/1000T with100/1000 SFP Combo Industrial Switch,
    Standard Operating Temperature (-20°C to 60°C)

  • IES-2307C-E...............…............P/N: 8350-465
    7 10/100TX + 3 10/100/1000T with100/1000 SFP Combo Industrial Switch,
    Wide Operating Temperature (-40°C to 75°C)

 

OPTIONAL ACCESSORIES

 
 

DIN Rail Power

  • AD1048-24FS
    24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
  • AD1024-24F
    24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
  • AD1240-48S
    48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
  • AD1120-48F
    48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
 

 

Mini GBIC

  • 8330-162 MINI GBIC 1000SX (LC/0.5km) Transceiver
  • 8330-163 MINI GBIC 1000SX2 (LC/2km) Transceiver
  • 8330-165 MINI GBIC 1000LX (LC/10km) Transceiver
  • 8330-166 MINI GBIC 1000LHX (LC/40km) Transceiver
  • 8330-169 MINI GBIC 1000XD (LC/60km) Transceiver
  • 8330-167 MINI GBIC 1000ZX (LC/80km) Transceiver
  • 8330-168 MINI GBIC 1000T (100m) Transceiver
  • 8330-061100Base LX 30KM, Single-mode, LC Transceiver
  • 8330-060100Base FX 2KM, Multi-mode, LC Transceiver
  • 8330-188 LTSFP-1000BX-10KM Transceiver (WDM 1310)
  • 8330-189 LTSFP-1000BX-10KM Transceiver (WDM 1550)
  • 8330-186 LTSFP-1000BX-20KM Transceiver (WDM 1310)
  • 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
  • 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
  • 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
  • 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
  • 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
  • 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
  • 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)

APPLICATIONS

 

 

DOWNLOADS

Description
Download

IES-2307C Datasheet

IES-2307C Manual

IES-2307C Firmware

 


 
Copyright 2009 Beijing Xiongyue Technology Co., Ltd. All Right Reserved