Hardware Specification |
Standards |
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX and 100Base-FX Fast Ethernet
IEEE802.3x Flow Control and Back Pressure |
Protocol |
CSMA/CD |
Transfer Rate |
14,880pps for Ethernet port
148,800pps for Fast Ethernet port |
Connectors |
SC (Multi-mode): 50/125um~62.5/125um
SC (Single-mode): 9/125um
Available distance: 2km (Multi-mode) / 30km(Single-mode)
Wavelength: 1310nm (Multi-mode/Single-mode)
10/100TX: 1 x RJ-45 with auto MDI/MDI-X function
[Multi-Mode] power budget: Min: 9dB, MAX: 19dB.
[Single-Mode] power budget: Min: 19dB, MAX: 26dB. |
Transfer packet size |
64bytes to 1522 bytes (with VLAN tag). |
Mac Address |
2K MAC address table |
Network Cable |
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5 cable
EIA/TIA-568 100-ohm (100m) |
DIP Switch |
DIP Switch 1: OFF: Disables Port /Power Alarm; ON: Enables Port /Power Alarm
DIP Switch 2: OFF: Disables LLF (Link Lose Forwarding) & LFP (Link Fault Pass-Through) ; ON: Enables LLF & LFP
DIP Switch 3: OFF: 100Base-FX Full-mode; ON: 100Base-FX Half-mode
DIP Switch 4: OFF: Switching mode; ON: Media mode (100TX to 100FX) |
Power Consumption |
2.74 Watts |
Reserve polarity protection |
Present |
Overload current protection |
Present |
LED |
Per unit: Power 1 (Green), Power 2 (Green), Fault(Red)
TX: Link/Active (Green), 100M(Yellow)
Fiber: Link/Active (Green), Full duplex/Collision (Yellow) |
Operating Humidity |
5% ~ 95% (Non-condensing) |
Operating Temperature |
-20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F (-E model) |
Storage Temperature |
-40°C~85°C / -40°F~185°F |
Case Dimension |
Metal case,IP-30; 30mm(W)x95mm(D)x140mm(H) |
Weight |
600 g |
EMI & EMS |
FCC Class A,
CE EN61000-4-2 (ESD),
CE EN61000-4-3 (RS),
CE EN61000-4-4 (EFT),
CE EN61000-4-5 (Surge),
CE EN61000-4-6 (CS),
CE EN61000-4-8,
CE EN61000-4-11,
CE EN61000-4-12,
CE EN61000-6-2,
CE EN61000-6-4 |
Safety |
UL, cUL, CE/EN60950
UL Class I Division II for Group A,B,C and D hazardous location |
Stability Testing |
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) |
MTBF |
405486 hrs |
Power Supply |
24 VDC (9~56VDC), 12~36VAC (Optional), Redundant power with polarity reverse protect function and removable terminal block |
Warranty |
5 years |